Sirius Mikro Micro-Incinerator

Where and what for

Micro-incinerator applications and Bunsen burner alternative

In any laboratory where you sterilize microbiology instruments such as loops and needles, you can use the Sirius micro-incinerator instead of a Bunsen burner, a laboratory burner, gas and an open flame.

Source-based

Clinical and hospital microbiology

Culture plating, colony picking, loop and needle sterilization. Work flame-free on tasks that repeat all day.

Source-based

Public health and reference laboratories

A flameless method that reduces aerosol formation in laboratories working with high-risk samples.

Source-based

Biosafety cabinets and laminar flow

Flameless sterilization instead of an open flame in the cabinet. It does not disturb the airflow or damage the filter.

Source-based

Research and biotechnology

Streaking, subculturing, colony picking and isolation work.

Source-based

Teaching and student laboratories

Students work safely without gas or an open flame.

General use

Enclosed environments where flames are unwanted

An electric solution for anaerobic work and areas where open flames are restricted.

General use

Food and beverage quality control

Routine microbiological plating and isolation.

General use

Water and environmental analysis

Sample plating and colony isolation.

General use

Pharmaceutical and cosmetic QC

Microbiology laboratory routines.

General use

Veterinary and agriculture

Plating and isolation in animal health and plant pathology laboratories.

Device feature

Pathology and cytology

Slide fixation.

Device feature

Culture tube mouths

Sterilization of the mouths of culture tubes.

Why flameless?

Biosafety and occupational safety guidelines advise against using an open flame in a Class II biosafety cabinet. Hot air rising from the flame disturbs the airflow in the cabinet and can damage the filter, and liquid samples can spatter in the flame and form aerosols. These guidelines mention enclosed, electric micro-incinerators as a flameless alternative.

This summarizes the general approach of university and institutional biosafety guidelines. Your own organization's rules also apply.

Disposable loops or a micro-incinerator?

Disposable loops are also a flameless option, but a new loop is used for every plating, so the amount of waste grows and that waste has to be decontaminated. With a micro-incinerator you reuse metal loops and needles again and again and reduce waste.

Comparison with a Bunsen burner

Points to keep in mind when using it

  • 1Place the loop or needle slowly into the device's quartz tube; placing it in too quickly can cause spattering.
  • 2Let the instrument cool for a short while before moving on to plating.
  • 3Reduce the liquid load on the loop; a thin film is enough.
  • 4Sterilize the instrument again between plating areas.
  • 5Do not rub the instrument against the tube wall or hold it in the tube longer than necessary.
  • 6Check the quartz tube regularly; the quartz tube is available as a spare part from the manufacturer.

These are general laboratory practice suggestions; the device's operating instructions and your organization's procedures take precedence.

An electric alternative to the Bunsen burner

A Bunsen burner, laboratory burner and lab gas burner are the same gas-fired laboratory device. The flameless alternative for loop sterilization is the electric micro-incinerator: no open flame, no gas line and no aerosol, and safe to use inside a biosafety cabinet.

All the same device

Bunsen burner, laboratory burner and lab gas burner all describe the same device: a laboratory heater that runs on natural gas or bottled gas and produces a single open flame. It is used for heating, sterilization and burning off.

A burner consists of a metal tube that sits on a base and a gas inlet at its bottom. Holes at the side of the tube are adjusted with a collar and let in the amount of air you want. The mixture of air and gas is ignited at the top of the tube.

With the air inlet closed, a yellow (safety) flame forms, which is cooler. With the air inlet open, a blue flame forms.

Limits of a gas burner in a microbiology laboratory

Open flame and fire risk

An added risk when alcohol and flammable liquids are nearby.

Aerosols

Liquid samples can spatter in the flame and form aerosols.

Biosafety cabinet

Hot air rising from the flame can disturb the airflow in the cabinet and damage the filter.

Infrastructure

Requires a gas line, tubing and a stand.

Comparison with the Sirius micro-incinerator

Comparison of a gas Bunsen burner and the Sirius micro-incinerator
FeatureGas Bunsen burnerSirius
EnergyNatural gas or bottled gasElectricity: 230 V input, 12 V heater
Open flameYesNone
AerosolCan form in the flamePrevented in the quartz tube
Biosafety cabinetCan affect airflow and filterDoes not disturb airflow or damage the filter
Extra equipmentTubing, stand, gas connectionNot required
OperationFlame has to be adjustedSwitch on and use; can be used with gloves
Typical tasksLoops, needles, tube mouths, heating vesselsLoops, needles, tube mouths, slide fixation
The micro-incinerator is designed for sterilizing loops and similar instruments, not for general heating such as warming vessels. If you also need general heating, a gas burner can stay on the bench; by leaving the frequent loop sterilization to the Sirius, you reduce the risk inside the cabinet.

Common questions about the Bunsen burner

Is a laboratory burner the same as a Bunsen burner?

Yes. Bunsen burner, laboratory burner and lab gas burner are different names for the same device. It is named after the German chemist Robert Bunsen, who developed it.

Can a micro-incinerator replace a Bunsen burner?

For sterilization tasks such as loops, needles, tube mouths and slide fixation, yes. It is not designed to heat vessels such as beakers or flasks; for that, use a heater or a gas burner.

Can I use a Bunsen burner in a biosafety cabinet?

Many university and institutional guidelines advise against using an open flame inside the cabinet. The flame disturbs the airflow and can damage the filter. A micro-incinerator is a flameless alternative.

Is a micro-incinerator also called an electric or infrared loop sterilizer?

Yes. Micro-incinerator, electric loop sterilizer, infrared loop sterilizer and bacti-cinerator are names commonly used for this class of device: an electrically heated tube in which loops and needles are sterilized without a flame.

Quote or spare parts request

For institutional purchases and spare parts requests, you can speak directly to the manufacturer.