Clinical and hospital microbiology
Culture plating, colony picking, loop and needle sterilization. Work flame-free on tasks that repeat all day.
Kadıköy, Istanbul+90 507 099 95 07info@siriusmikro.com
Where and what for
In any laboratory where you sterilize microbiology instruments such as loops and needles, you can use the Sirius micro-incinerator instead of a Bunsen burner, a laboratory burner, gas and an open flame.
Culture plating, colony picking, loop and needle sterilization. Work flame-free on tasks that repeat all day.
A flameless method that reduces aerosol formation in laboratories working with high-risk samples.
Flameless sterilization instead of an open flame in the cabinet. It does not disturb the airflow or damage the filter.
Streaking, subculturing, colony picking and isolation work.
Students work safely without gas or an open flame.
An electric solution for anaerobic work and areas where open flames are restricted.
Routine microbiological plating and isolation.
Sample plating and colony isolation.
Microbiology laboratory routines.
Plating and isolation in animal health and plant pathology laboratories.
Slide fixation.
Sterilization of the mouths of culture tubes.
Biosafety and occupational safety guidelines advise against using an open flame in a Class II biosafety cabinet. Hot air rising from the flame disturbs the airflow in the cabinet and can damage the filter, and liquid samples can spatter in the flame and form aerosols. These guidelines mention enclosed, electric micro-incinerators as a flameless alternative.
This summarizes the general approach of university and institutional biosafety guidelines. Your own organization's rules also apply.
Disposable loops are also a flameless option, but a new loop is used for every plating, so the amount of waste grows and that waste has to be decontaminated. With a micro-incinerator you reuse metal loops and needles again and again and reduce waste.
Comparison with a Bunsen burnerThese are general laboratory practice suggestions; the device's operating instructions and your organization's procedures take precedence.
A Bunsen burner, laboratory burner and lab gas burner are the same gas-fired laboratory device. The flameless alternative for loop sterilization is the electric micro-incinerator: no open flame, no gas line and no aerosol, and safe to use inside a biosafety cabinet.
Bunsen burner, laboratory burner and lab gas burner all describe the same device: a laboratory heater that runs on natural gas or bottled gas and produces a single open flame. It is used for heating, sterilization and burning off.
A burner consists of a metal tube that sits on a base and a gas inlet at its bottom. Holes at the side of the tube are adjusted with a collar and let in the amount of air you want. The mixture of air and gas is ignited at the top of the tube.
With the air inlet closed, a yellow (safety) flame forms, which is cooler. With the air inlet open, a blue flame forms.
An added risk when alcohol and flammable liquids are nearby.
Liquid samples can spatter in the flame and form aerosols.
Hot air rising from the flame can disturb the airflow in the cabinet and damage the filter.
Requires a gas line, tubing and a stand.
| Feature | Gas Bunsen burner | Sirius |
|---|---|---|
| Energy | Natural gas or bottled gas | Electricity: 230 V input, 12 V heater |
| Open flame | Yes | None |
| Aerosol | Can form in the flame | Prevented in the quartz tube |
| Biosafety cabinet | Can affect airflow and filter | Does not disturb airflow or damage the filter |
| Extra equipment | Tubing, stand, gas connection | Not required |
| Operation | Flame has to be adjusted | Switch on and use; can be used with gloves |
| Typical tasks | Loops, needles, tube mouths, heating vessels | Loops, needles, tube mouths, slide fixation |
Yes. Bunsen burner, laboratory burner and lab gas burner are different names for the same device. It is named after the German chemist Robert Bunsen, who developed it.
For sterilization tasks such as loops, needles, tube mouths and slide fixation, yes. It is not designed to heat vessels such as beakers or flasks; for that, use a heater or a gas burner.
Many university and institutional guidelines advise against using an open flame inside the cabinet. The flame disturbs the airflow and can damage the filter. A micro-incinerator is a flameless alternative.