Hospital microbiology
Culture plating, colony picking, loop and needle sterilization.
Kadıköy, Istanbul+90 507 099 95 07info@siriusmikro.com
Manufacturer · Kadıköy / Istanbul
Sirius is an electric loop sterilizer that replaces the Bunsen burner. It sterilizes inoculation loops and needles inside a quartz tube in approximately 2–4 seconds.
Call us: +90 507 099 95 07

Why Sirius
Take the most frequent task in your microbiology lab off the flame and the gas line.

Plug it in and use it. No gas line, tubing or open flame.
The sample is sterilized inside the quartz tube, so liquid samples do not form aerosols.
It does not disturb the airflow in a biosafety cabinet and protects the cabinet filter.
Comfortable to use with gloves. The outer surface can be touched during operation.
An energy-efficient, environmentally friendly electronic circuit design.
Rotate the device and work at the angle that suits you.
Bunsen burner alternative
Open-flame laboratory burners can disturb the airflow in a biosafety cabinet and damage the filter. A micro-incinerator does the same job without a flame.
| Feature | Gas Bunsen burner | Sirius |
|---|---|---|
| Energy | Natural gas or bottled gas | Electricity |
| Open flame | Yes | None |
| Aerosol | Can form in the flame | Prevented in the quartz tube |
| Biosafety cabinet | Can affect airflow and filter | Does not disturb airflow or damage the filter |
| Extra equipment | Tubing, stand, gas connection | Not required |


Product brochure
Download the brochure and share it within your organization. It includes QR codes for quotes and spare parts requests.
We are the manufacturer. The device is supplied to many hospitals and laboratories. Sales and spare parts come directly from us.
Applications
Culture plating, colony picking, loop and needle sterilization.
Flameless sterilization instead of an open flame in the cabinet.
Streaking, subculturing and colony picking.
Students work without gas or an open flame.
Routine microbiological plating.
Sample plating and isolation work.
Microbiology laboratory routines.
Animal health and plant pathology laboratories.
Spare parts
As the manufacturer, we supply and replace all parts, either on site or after you send the device to us. Send your parts request by form, WhatsApp or phone.
Frequently asked questions
A micro-incinerator is a benchtop device that sterilizes microbiology instruments such as inoculation loops and needles electrically, without an open flame. The instrument is sterilized in a few seconds inside a heated tube.
A Bunsen burner runs on gas and produces an open flame. A micro-incinerator runs on electricity and sterilizes inside a quartz tube. No gas connection is needed and aerosol formation is prevented.
Loops and needles are sterilized in approximately 2–4 seconds.
Yes. Unlike an open-flame burner, it does not disturb the airflow inside the cabinet and does not damage the cabinet filter.
Yes. The device is designed for comfortable use with gloves.
It runs on a 230 V mains supply. An internal transformer steps the voltage down to 12 V, and the heating section operates at 12 V.
For institutional purchases and spare parts requests, you can speak directly to the manufacturer.