Sirius Mikro Micro-Incinerator

Manufacturer · Kadıköy / Istanbul

Micro-incinerator: flameless, aerosol-free loop sterilization

Sirius is an electric loop sterilizer that replaces the Bunsen burner. It sterilizes inoculation loops and needles inside a quartz tube in approximately 2⁠–⁠4 seconds.

Call us: +90 507 099 95 07

Sirius micro-incinerator shown from two angles: quartz tube upright and tilted
2-year warrantyManufacturer warranty
Close-up
All angles
  • Manufacturer spare partsAll parts from us
  • Fast worldwide shippingFrom stock, via micro-export
  • 2-year warrantyManufacturer warranty
  • Parts replacementOn site or by shipping
~1000 °C
Sterilization temperature
2⁠–⁠4 s
Loops and needles
12 V
Heater voltage
270°
Rotation
Ø22×100
Quartz tube (mm)
2 years
Warranty

Why Sirius

A safe electric burner instead of flame and gas

Take the most frequent task in your microbiology lab off the flame and the gas line.

Sirius micro-incinerator with the quartz tube in the tilted working position

No flame, no gas

Plug it in and use it. No gas line, tubing or open flame.

Prevents aerosols

The sample is sterilized inside the quartz tube, so liquid samples do not form aerosols.

Safe for cabinet filters

It does not disturb the airflow in a biosafety cabinet and protects the cabinet filter.

Use with gloves

Comfortable to use with gloves. The outer surface can be touched during operation.

Low energy use

An energy-efficient, environmentally friendly electronic circuit design.

270° rotation

Rotate the device and work at the angle that suits you.

Bunsen burner alternative

Instead of a Bunsen burner or laboratory burner

Open-flame laboratory burners can disturb the airflow in a biosafety cabinet and damage the filter. A micro-incinerator does the same job without a flame.

  • No gas line, tubing or stand required
  • Sterilization in a quartz tube, no aerosol
  • Safe to use inside the cabinet
Detailed comparison
Comparison of a gas Bunsen burner and the Sirius micro-incinerator
FeatureGas Bunsen burnerSirius
EnergyNatural gas or bottled gasElectricity
Open flameYesNone
AerosolCan form in the flamePrevented in the quartz tube
Biosafety cabinetCan affect airflow and filterDoes not disturb airflow or damage the filter
Extra equipmentTubing, stand, gas connectionNot required
Product brochure, page 1Product brochure, page 2

Product brochure

Everything on 2 pages: features, technical summary and spare parts

Download the brochure and share it within your organization. It includes QR codes for quotes and spare parts requests.

We are the manufacturer. The device is supplied to many hospitals and laboratories. Sales and spare parts come directly from us.

Applications

From hospital labs to teaching laboratories

All applications

Hospital microbiology

Culture plating, colony picking, loop and needle sterilization.

Biosafety cabinets

Flameless sterilization instead of an open flame in the cabinet.

Research and biotechnology

Streaking, subculturing and colony picking.

Teaching laboratories

Students work without gas or an open flame.

Food and beverage quality control

Routine microbiological plating.

Water and environmental analysis

Sample plating and isolation work.

Pharmaceutical and cosmetic QC

Microbiology laboratory routines.

Veterinary and agriculture

Animal health and plant pathology laboratories.

Spare parts

Spare parts from the manufacturer

As the manufacturer, we supply and replace all parts, either on site or after you send the device to us. Send your parts request by form, WhatsApp or phone.

Frequently asked questions

Common questions

All questions
What is a micro-incinerator and what is it used for?

A micro-incinerator is a benchtop device that sterilizes microbiology instruments such as inoculation loops and needles electrically, without an open flame. The instrument is sterilized in a few seconds inside a heated tube.

How is it different from a Bunsen burner?

A Bunsen burner runs on gas and produces an open flame. A micro-incinerator runs on electricity and sterilizes inside a quartz tube. No gas connection is needed and aerosol formation is prevented.

How long does sterilization take?

Loops and needles are sterilized in approximately 2⁠–⁠4 seconds.

Can it be used in a biosafety cabinet?

Yes. Unlike an open-flame burner, it does not disturb the airflow inside the cabinet and does not damage the cabinet filter.

Can I use it while wearing gloves?

Yes. The device is designed for comfortable use with gloves.

What voltage does it run on?

It runs on a 230 V mains supply. An internal transformer steps the voltage down to 12 V, and the heating section operates at 12 V.

Quote or spare parts request

For institutional purchases and spare parts requests, you can speak directly to the manufacturer.